AngioScan diagnostic complex

AngioScan-01 - Brief description

“AngioScan-01” is a professional diagnostic device for assessment of arterial function state.

(Dual-channel clinical version AngioScan device)


Diagnostic device “AngioScan-01” is represented by hardware (a device) and “AngioScan” software for PC.


“AngioScan-01” device is a dual-channel version designed for use in medical institutions by professionally trained medical personnel. Among other AngioScan devices, “AngioScan-01” analyses the widest range of cardiovascular system parameters.


AngioScan-01


Two channels for photoplethysmography sensors connection are the main distinctive feature of “AngioScan-01”, which makes possible to perform an occlusion test evaluating state of endothelial function. A pharmacological test for assessing the effectiveness of therapy, food supplies, foodstuffs etc. can also be performed.


AngioScan is an innovative technology created for performing a noninvasive examination of heart and vessels by assessing the state of arterial function. The term "arterial function" concerns such parameters as stiffness of arterial wall and state of endothelium. The technology allows one easily and reliably check the heart, and to make early diagnosis of cardiovascular diseases.


Diagnostic complex “AngioScan – 01” is based on recording a pulse wave by an optical sensor operating in the near infrared. The signal received gives a detailed information about the state of stiffness of arterial wall. The occlusion test evaluates the state of endothelial function.


The unique feature of the technology is a contour analysis, performed for analysis of stiffness of arterial wall and simultaneous assessment of vasomotor endothelial function. At the same time the state of the endothelium in small (resistive) and large (conductive) arteries is assessed.


The advantages of a diagnostic system "AngioScan - 01" are the following:


  • Ease of testing;
  • Automatic analysis of the parameters tested;
  • The stiffness of the arterial wall is assessed by evaluating of augmentation index with the visualization of early and late systolic waves;
  • Assessment of endothelial function in small (resistive) and large (conductive) arteries;
  • Evaluation of the central arterial blood pressure.

AngioScan software’ graphical interface provides an operator easy access to all the functionality of the device:


  • Database with personal data of all patients and the test results;
  • Export and import of databases;
  • Charting of trends for all selected test parameters, which allows one to monitor the effectiveness of the therapy;
  • Conducts all types of tests: the contour analysis, occlusion tests, pharmacological tests;
  • Represents the parameters tested on a PC display during the tests;
  • Built-in tools for detailed examination of pulse waves after the test.

Examples of the AngioScan software interface:


AngioScan-01 interface

AngioScan-01 interface




АнгиоСкан АнгиоСкан АнгиоСкан